Refine your search:     
Report No.
 - 
Search Results: Records 1-4 displayed on this page of 4
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Activation energy of diffusivities for deuterated water in compacted sodium-bentonite; Through-diffusion experiment and molecular dynamics simulation

Suzuki, Satoru; Sato, Haruo; Ishidera, Takamitsu; Fujii, Naoki*; Kawamura, Katsuyuki*

JNC TN8400 2001-031, 44 Pages, 2002/05

JNC-TN8400-2001-031.pdf:1.58MB

In order to quantify effect of temperature on diffusivity of deuterated water (HDO) in compacted sodium-bentonite, through-diffusion experiments were conducted at elevated tempemture from 298 to 333 K. Kunipia F (Na-montmorillonite content $$>$$ 98 wt. %; Kunimine Industly Co.) was compacted to a dry density of 0.9 and l.35 Mg/m$$^{3}$$. Since smectite flakes were perpendicularly oriented to a direction of compaction, anisotropy of diffusivity was investigated parallel and normal to the preferred orientation of smectite. Effective diffusion coeficient D$$_{e}$$ of HDO was larger for a diffusional direction parallel to the preferred orientation than normal to that for both dry densities. These results well agreed to the previously reported ones for tritiated water. Activation energies of D$$_{e}$$ in compacted bentonite increased with increasing dry density in the range of 19 - 25 kJ/mol which was slightly larger than that in bulk water (18 kJ/mol). This relationship can be considered to be due to both the pore structure development and high activation energy of water (18-23 kJ/mol) in the vicinity of smectite surface (within 2 nm) on the basis of molecular dynamics simulations.

JAEA Reports

A Study of structure of base-isolated

; ; Yamazaki, Toshihiko; ; ; Kondo, Toshinari*; *

JNC TN8400 2001-030, 99 Pages, 2002/01

JNC-TN8400-2001-030.pdf:13.24MB

There is a great deal of that we build a Base-Isolated building with the quaternary deposit ground. In an atomic energy institution, a study request is strong. When we build a Base-Isolated building with the quaternary deposit ground, evaluation of earthquake vibration of a vertical direction is an important problem. In an atomic energy institution, we design it by big earthquake load, and therefore examination is necessary. And, in this study, we do examination to build a Base-Isolated building with the quaternary deposit ground, we report it about an evaluation method of a design. Furthermore, we report that we estimated pipe laying and machinery to put in a building of Base-lsolated.

JAEA Reports

A Development of simulation and analytical program for through-diffusion experiments for a single layer of diffusion media

Sato, Haruo

JNC TN8410 2001-003, 40 Pages, 2001/01

JNC-TN8410-2001-003.pdf:1.13MB

A program (TDROCK1.FOR) for simulation and analysis of through-diffusion experiments for a single layer of diffusion media was developed. This program was made by Pro-Fortran language, which was suitable for scientific and technical calculations, and relatively easy explicit difference method was adopted for an analysis. In the analysis, solute concentration in the tracer cell as a function of time that we could not treat to date can be input and the decrease in the solute concentration as a function of time by diffusion from the tracer cell to the measurement cell, the solute concentration distribution in the porewater of diffusion media and the solute concentration in the measurement cell as a function of time can be calculated. In addition, solution volume in both cells and diameter and thickness of the diffusion media are also variable as an input condition. This simulation program could well explain measured result by simulating solute concentration in the measurement cell as a function of time for case which apparent and effective diffusion coefficients were already known. Based on this, the availability and applicability of this program to actual analysis and simulation were confirmed. This report describes the theoretical treatment for the through-diffusion experiments for a single layer of diffusion media, analytical model, an example of source program and the manual.

JAEA Reports

Development of analytical method for plutonium in high active liquid waste solution by high performance spectrophotometry

Jitsukata, Shu*; *; ; ; Kurosawa, A.

JNC TN8410 2001-002, 66 Pages, 2000/12

JNC-TN8410-2001-002.pdf:2.03MB

It was required from IAEA to determine a small amount of plutonium in the high active liquid waste solutions (HALW) in the tokai reprocessing plant. High performance spectrophotometer (HPSP), which could be obtained lower detection limit than conventional spectrophotometer, is studied to be applied to the inspection and verification analysis by the IAEA. [Cold Test] Neodymium, showing an absorption peak near the absorption wavelength of plutonium (VI), was used as an alternative element to plutonium, in order to review the calculation method of the peak intensity. As a result, the three-point correction method was found to be simple and effective. [Hot Test] Plutonium nitrate solution was used the fundamental test of this method. Since the method is known to be influenced by acidity, suspended sludge and coexistent elements in a sample, each dependency was examined. It was found that measurement results varied about 14% at a nitric acid concentration of 2-4 mol/L. Sludge should be removed by filtration before the measurement. The effect of coexisting elements could be eliminated adjusting the optical balance between reference and sample beam intensity. In the case of measuring a low concentration plutonium solution sample, a ratio of the peak intensity to the background intensity (S/B ratio) is relatively small. Therefore a method should be improved the S/B ratio by analyzing the obtained spectra. Accumulated average method, moving average method and Fourier transform method was tested. The results showed that a combination of the accumulated average method and the moving average method was the optimum method for the purpose. Linearity of the calibration curve was found between 0-11 mgPu/L. Synthetic sample solution, which simulated the actual constituents of the HALW with plutonium showed a good linear relation at 0-11 mgPu/L. The detection limit for plutonium concentration was 0.07 mgPu/L. When the synthetic HALW solution containing plutonium was measured, the de

4 (Records 1-4 displayed on this page)
  • 1